extractor array front

The e-Array ScCO2 Extractor


The E-Array Supercritical CO2 Extractor FEATURES & BENEFITS

PROCESSING POWER:
Co-solvent pump, configurable; 0-5,000 psi/345bar; 0° – 100° C; up to 200 L collection capacity; Flow rate, configurable; Optional pump for solvent or cleaning methods

GMP COMPLIANCE:
Automated process control; Batch, operator, parameter tracking; FDA approved materials & surface finishes; GAMP5 CAT3; Instrument calibrations; Clean in place; International certifications; Calibration/maintenance tracking

PROCESSING CONTROL:
Programmable methods including co-solvent, temp and timed delays and gradients; Automated extraction cycles; Independent vessel control; Automated temp & pressure control; Cyclonic collection; Data capture/reporting; Automation sold separately; Upstream containment & automation integration


General Specifications

CERTIFICATIONS, Listed:
UL 508A, CE, PED, GAMP5

REGULATORY COMPLIANCE:
21 CFR Part 117, 211, 177 and Health Canada equivalents, P.E. stamped according to ASME DIV II VII-2, PED, CE marked, notified body Lloyd’s Register, CRN

ALSO AVAILABLE, SOLD SEPARATELY:
GMP Documentation Package; Commissioning and Training Package; Maintenance Package (12 Months)

WARRANTY:
12 months for quality, labor, parts, and workmanship on United Science equipment.


related equipment